NEW QUESTION 60
When installing the UPS battery, the installation tool does not need to be insulated because the load is not charged.
- A. True
- B. False
Answer: B
NEW QUESTION 61
The NetCol 8000-A100kW is dual-system and comes standard with a single indoor unit connected to an outdoor unit.
- A. True
- B. False
Answer: B
NEW QUESTION 62
In the air conditioning system, the pipe can maintain a positive pressure and the pipe can maintain a negative pressure.
- A. True
- B. False
Answer: B
NEW QUESTION 63
The access executor does not support access to the ECC800 in a wireless network.
- A. True
- B. False
Answer: B
NEW QUESTION 64
When the UPS5000-E is installed in parallel, it is not necessary to connect the UPS parallel lines of the parallel system into a loop.
- A. True
- B. False
Answer: B
NEW QUESTION 65
The following () parts can control the room lighting and control the Pad charging.
- A. Smart ETH socket
- B. Actuator
- C. Access control actuator
- D. Cabinet collector
Answer: B
NEW QUESTION 66
Huawei NeCol5000-A row-level precision air conditioner eliminates local hot spots by means of near-end cooling.
- A. True
- B. False
Answer: A
NEW QUESTION 67
In the "Video" function of NetEco, you can perform operations such as (). (Multiple Choice)
- A. Video live browsing
- B. Create a camera
- C. Modify the camera
- D. Delete the camera
Answer: A,B,C,D
NEW QUESTION 68
To use the NetEco APP on PAD to query the PUE information of the current computer room, you need to click the () menu.
- A. Alarm
- B. More
- C. Energy consumption
- D. Monitoring
Answer: C
NEW QUESTION 69
If the status of the access which collected by the network management is always open, it can be checked by (). (Multiple choice)
- A. Check if the suction plate angle and tightness on the door are suitable
- B. Check if the door of access monitoring is closed
- C. Check if the access control actuator and the door magnetic lock wiring are normal.
- D. Check AC actuator wiring
Answer: A,B,C
NEW QUESTION 70
The sunroof actuator can control the flip sunroof of the modular data center closed channel.
- A. True
- B. False
Answer: A
NEW QUESTION 71
The principle of the () humidifier is that the high-intensity infrared lamp causes the water surface to release water vapor and diffuse into the air stream that needs to be humidified.
- A. Electrode
- B. High pressure fogging
- C. Infrared
- D. Wet film
Answer: C
NEW QUESTION 72
When the UPS5000-E is equipped with an IP21 component, the ejector component can also be installed.
- A. True
- B. False
Answer: B
NEW QUESTION 73
Domains can be created in NetEco, such as campuses, buildings, machine rooms, containers, etc.
- A. FALSE
- B. TRUE
Answer: B
NEW QUESTION 74
After the UPS5000-E system is installed, which of the following items need to be checked? (Multiple choice)
- A. if US and battery system mechanical installation is firm and stable
- B. if the cable layout considers other system wiring in the future.
- C. The positive and negative terminals of the battery are wired correctly.
- D. if the ground connection is reliable
Answer: A,B,C,D
NEW QUESTION 75
The dry contact signal of the UPS5000-E does not support the remote emergency stop function.
- A. True
- B. False
Answer: B
NEW QUESTION 76
......