NEW QUESTION # 51
What is the default amount of historical data needed for calculating capacity forecast?
- A. 7 to 30 days
- B. 7 to 180 day
- C. 1 to 30 days
- D. 1 to 90 days
Answer: B
NEW QUESTION # 52
If an SNMP community string is changed on a device, which two of the following steps are required to re- establish successful polling on the node? (Choose two.)
- A. Restart the SNMP service on the source device.
- B. Update the community string in node properties.
- C. Delete and add the node back into the platform.
- D. Edit the node properties and save the changes.
Answer: B,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
When the SNMP community string is changed on a device, SolarWinds recommends:
Edit the node properties and save the changes.
Update the community string in node properties to match the new value on the device.
"To restore polling, edit the node in SolarWinds, update the SNMP community string in the properties, and save the changes. This ensures that SolarWinds can authenticate and resume polling. Deleting and re-adding the node is not necessary, nor is restarting the SNMP service on the device in most cases." References:
Network Performance Monitor Administrator Guide, Section: "SNMP Node Management" SolarWinds Success Center: "Updating SNMP Credentials"
NEW QUESTION # 53
Which statement depicts the relationship between device studio pollers' supported technologies and universal device pollers' (UDPs) supported technologies?
- A. device studio pollers can poll for node details of SNMP enabled devices, UDPs cannot
- B. UDPs can poll for memory utilization of SNMP enabled devices, device studio pollers cannot
- C. UDPs can poll for hardware status of SNMP enabled devices, device studio pollers cannot
- D. device studio pollers can poll for CPU utilization of SNMP enabled devices, UDPs cannot
Answer: C
NEW QUESTION # 54
Which three of the following settings can be used to customize the thresholds for an object in SolarWinds' platform? (Choose three.)
- A. single poll
- B. X concurrent polls
- C. X consecutive polls
- D. X of Y polls
Answer: A,C,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
SolarWinds platform allows for customizing threshold behavior to reduce false positives and tune alerting sensitivity. The three primary customizable threshold settings are:
Single poll: A threshold is triggered immediately if the value breaches the limit in a single polling cycle.
X consecutive polls: The threshold must be exceeded in X consecutive polling intervals before being considered breached.
X of Y polls: The threshold is triggered if the value exceeds the limit in X out of Y most recent polls.
"X concurrent polls" is not an available threshold customization in the SolarWinds platform.
Reference:
SolarWinds Platform Administrator Guide, "Threshold Customization Options,"
"You can trigger thresholds based on single poll, X consecutive polls, or X of Y polls..."
NEW QUESTION # 55
What is the most efficient way to create a custom NetFlow view to access at a later time?
- A. Create the view from NetFlow settings and save to menu bar.
- B. Create the view from flow navigator and click the submit button.
- C. Create the view from flow navigator and save to the menu bar.
- D. Create the view from charting and graphing in NetFlow settings.
Answer: C
NEW QUESTION # 56
A network discovery profile for a network area completes with most devices discovered, except for a few SNMP-enabled network devices. These undiscovered devices are verified to be operational and respond to SNMP queries.
What could be the cause?
- A. no SNMP pollers match the device
- B. SNMP community strings in profile are invalid
- C. device MIB is not in SolarWinds' MIB database
- D. discovery timeout value is set too low
Answer: D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
If devices respond to SNMP queries individually but aren't discovered during network scans, the most likely cause is the discovery timeout value being set too low. This can result in slower devices timing out before responding to discovery requests, even though they are operational and SNMP-enabled.
The documentation explains:
"If devices are not discovered but respond to SNMP queries, increase the discovery timeout and retry. Short timeouts can cause missed responses from devices that take longer to reply during scanning." References:
Network Performance Monitor Administrator Guide, Section: "Discovery Troubleshooting" SolarWinds Success Center: "Device Not Found During Discovery"
NEW QUESTION # 57
In which scenario would the device studio poller tool be considered the best tool for building a required poller?
- A. Building a poller to show CPU and memory status.
- B. Building a poller to add missing information to node details.
- C. Building a poller to monitor VPN tunnel status.
- D. Building a poller for ARP tables to display in the web console.
Answer: B
NEW QUESTION # 58
Which tool can be used to display the physical layout of interfaces on graphical stencils?
- A. network insight
- B. device studio
- C. NetPath
- D. device view
Answer: D
Explanation:
The "Device View" feature allows users to view the physical layout of device interfaces on graphical stencils, providing an intuitive graphical representation of port locations and status.
Exact Extract from Official Guide:
"Device View displays the physical layout of device interfaces using graphical stencils for supported devices."
- (Network Performance Monitor Administrator Guide, "Device View" section) References:
Network Performance Monitor Administrator Guide, Device View
NEW QUESTION # 59
Which two of the following statements explain creating alerts for NBAR2 applications? (Choose two.)
- A. It is possible to combine applications and NBAR2 applications.
- B. Applications and NBAR2 applications in top applications are sorted by bits.
- C. Applications and NBAR2 applications in top applications are sorted by bytes.
- D. It is not possible to combine applications and NBAR2 applications.
Answer: A,C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Applications and NBAR2 applications in top applications are sorted by bytes: The default sorting for the "Top Applications" view, including NBAR2 apps, is by bytes.
It is possible to combine applications and NBAR2 applications: SolarWinds allows combining standard and NBAR2-classified apps for alerting and reporting purposes.
Exact Extract from Official Guide:
"Top Applications, including NBAR2, are sorted by bytes and you can combine standard and NBAR2 application data in alerts and reports."
- (Network Performance Monitor Administrator Guide, "NBAR2 Applications" section) References:
Network Performance Monitor Administrator Guide, NBAR2 Applications
NEW QUESTION # 60
Which three of the following devices are supported on SolarWinds' hybrid cloud observability IP flow monitor? (Choose three.)
- A. nFlow
- B. J-Flow
- C. sFlow
- D. IPF1X
Answer: B,C,D
NEW QUESTION # 61
In device studio, which three of the following technologies are supported for custom polling? (Choose three.)
- A. multi-CPU / memory
- B. single CPU / memory
- C. interface traffic
- D. node details
Answer: A,B,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Device Studio supports advanced custom polling, allowing you to build pollers for technologies such as multi- CPU/memory, node details (e.g., chassis, serial number), and single CPU/memory. While interface traffic polling is best accomplished through standard interface resources, Device Studio is designed for more advanced or complex device metrics that are not available via built-in polling.
Reference:
Network Performance Monitor Administrator Guide, "Device Studio Supported Technologies,"
"Device Studio supports polling for multi-CPU/memory, node details, and single CPU/memory, providing deep visibility into device-specific metrics."
NEW QUESTION # 62
What is needed to edit trigger conditions in flow alerts?
- A. SQL
- B. PowerShell
- C. SWQL
- D. Python
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To edit trigger conditions for flow alerts in SolarWinds, the SolarWinds Query Language (SWQL) is required. SWQL is a proprietary subset of SQL designed specifically for the SolarWinds Orion Platform. The documentation specifies:
"Editing advanced alert trigger conditions and custom queries for flow-based alerts requires the use of SWQL, not PowerShell, Python, or standard SQL." References:
NPM Administrator Guide: Alerting and SWQL for Advanced Flow Alert Triggers
NEW QUESTION # 63
Which two of the following functions are tied to SolarWinds' MIB database? (Choose two.)
- A. SolarWinds' MIB database maps object IDs (OIDs) to their textual names.
- B. SolarWinds' MIB database updates OIDs on the device during the polling process.
- C. SolarWinds' MIB database defines what kind of pollers can be built for the metric.
- D. SolarWinds' MIB database enables automatic polling of devices.
Answer: A,C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
The SolarWinds MIB database is used for SNMP-based monitoring and performs these critical functions:
A). It defines which OIDs are recognized and what metrics can be polled via Universal Device Pollers or other custom monitors.
C). It maps OIDs (numeric identifiers) to their human-readable textual names for reporting and alerting.
Options B and D are not accurate; the database does not enable automatic polling nor does it update device OIDs during polling.
References:
SolarWinds MIB database overview - SolarWinds NPM Administrator Guide, MIBs and OIDs section
NEW QUESTION # 64
To drill down into a log summary for a specific node, where in SolarWinds' platform can a user view these logs?
- A. Node Details Summary > Management > Analyze Logs
- B. Node Details Summary > Management > List Resources
- C. Alerts & Activity > Message Center
- D. My Dashboard > Logs > Log Viewer
Answer: A
NEW QUESTION # 65
On a single node, one or more interfaces are showing an "unknown" status. What is the best way to resolve the issue?
- A. Verify the interfaces are assigned to SolarWinds' native poller.
- B. Delete and rediscover the node showing affected interfaces.
- C. Delete and re-add the affected interfaces.
- D. Change node's pollingmethod to ICMP.
Answer: C
NEW QUESTION # 66
After creating a new device studio poller that appears to be returning values on a test device, it is then applied to additional nodes. One of these new devices is not returning the statistics of the test node. Which two of the following reasons might be the cause of the issue? (Choose two.)
- A. object IDs (QIDs) are not supported
- B. communication issue exists in new device
- C. new device needs to be rebooted
- D. devices have different firmware versions
Answer: A,D
NEW QUESTION # 67
In customizing the flow direction of SolarWinds' platform views, which statement is true?
- A. Both ingress and egress views are available for the next two sessions.
- B. Both ingress and egress views are available for 24 hours.
- C. Both ingress and egress views are available for 48 hours.
- D. Both ingress and egress views are available for the current session only.
Answer: D
NEW QUESTION # 68
Which two of the following troubleshooting steps can be performed when a node is "up" and the data cannot be found in SolarWinds' platform web console? (Choose two.)
- A. Add a remote site node and make sure the firewall rules are configured to allow SNMP traffic.
- B. Verify hardware health sensors on the device provide both status and values.
- C. Ping the device from the polling engine the device is assigned to using the command line.
- D. Wait ten minutes after a device is added to the console. Refresh the screen.
Answer: B,C
Explanation:
Ping the device from the polling engine: Verifies network connectivity and correct polling engine assignment.
Verify hardware health sensors: Ensures the platform is receiving valid sensor data; missing data may indicate sensor or device communication issues.
Adding a remote site node and waiting are not direct troubleshooting steps for missing data on a node that is already "up." Exact Extract from Official Guide:
"If a node is up but data is missing, check network connectivity from the polling engine using ping or SNMP walk tools, and verify that hardware health sensors are reporting valid data."
- (Network Performance Monitor Administrator Guide, "Troubleshooting Nodes and Data Collection" section) References:
NEW QUESTION # 69
When attempting to add universal device poller (UDP) results to a new chart widget, none of the custom poller results are displayed. If the web console switches to another view, the data appears in the chart. What is the most likely resolution?
- A. UDP application under web display, chart box must be checked for each view to be used
- B. unassign and reassign custom poller in UDP application
- C. UDP application, click transform results to convert them into a format viewable in a chart
- D. user does not have correct permissions to view the data
Answer: A
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
When displaying Universal Device Poller (UDP) data in different web console views, each view must be configured to show the UDP results as charts.
From the documentation:
"In the Universal Device Poller application, under the Web Display tab, you must check the 'chart' box for every web view where you want to display the poller data. If the box is not checked for the current view, the data will not be visible as a chart widget." References:
NPM Administrator Guide: Universal Device Poller - Web Display Settings
NEW QUESTION # 70
A new node has been added to hybrid cloud observability; however, certain data being polled on similar devices is not being polled on the new node. How can this be resolved?
- A. UDP must be re-created for new node
- B. assign the new node to the same polling engine
- C. assign existinguniversal device poller (UDP) to new node
- D. verily the credentials for the new node are valid
Answer: C
NEW QUESTION # 71
SNMP get type defines the SNMP polling method used by a universal device poller (UDP) to get the device's object ID (OID) values.
Which SNMP get type retrieves values from a particular column?
- A. next
- B. data
- C. column
- D. table
Answer: D
NEW QUESTION # 72
Which port allows log analysis in the SolarWinds platform to accept secure syslog messages?
- A. UDP port 10514
- B. TCP port 6514
- C. UDP port 514
- D. TCP port 601
Answer: B
NEW QUESTION # 73
......
Hybrid-Cloud-Observability-Network-Monitoring exam questions from Free4Torrent dumps: https://braindumps.free4torrent.com/Hybrid-Cloud-Observability-Network-Monitoring-valid-dumps-torrent.html (152 Q&As)